{"product_id":"2-1-2-commercial-riser-with-pressure-reducing-valve","title":"2-1\/2\" Commercial Riser With Pressure Reducing Valve","description":"\u003cdiv\u003e\n\u003cp\u003e\nThe 2-1\/2\" Commercial Riser with Pressure Reducing Valve by AGF is a robust fire protection part engineered for commercial fire suppression systems. Designed to ensure reliable water pressure control, it is ideal for building managers and fire safety professionals seeking compliance with NFPA 13 standards.\n\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eConstruction Material\u003c\/b\u003e: Crafted with durable bronze and brass components to resist corrosion and endure harsh fire system environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eIntegrated Pressure Reducing Valve\u003c\/b\u003e: Automatically regulates water pressure to maintain optimal flow, safeguarding sprinkler systems from damage due to excessive pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompliance\u003c\/b\u003e: Fully meets NFPA 13 fire protection requirements, ensuring safety and regulatory adherence for commercial installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInlet and Outlet Connections\u003c\/b\u003e: Designed with grooved and threaded Schedule 10 steel pipe fittings to support easy integration into existing piping systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eTesting and Maintenance Features\u003c\/b\u003e: Includes AGF’s TESTanDRAIN valve and a built-in test port allowing hydrostatic testing without draining the system, simplifying routine inspections and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePressure Gauge and Control Valve\u003c\/b\u003e: Comes equipped with precision pressure gauges and a 3-way gauge control valve for accurate pressure monitoring and control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eField-Serviceable Components\u003c\/b\u003e: Standard components like pressure gauges and flow switches are designed to be replaceable on-site, minimizing downtime.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003e\nThis commercial riser assembly enhances fire protection system reliability by maintaining consistent water pressure, preventing damage and failures caused by pressure fluctuations. Its design reduces installation complexity and supports efficient testing without system downtime. Suitable for a broad range of commercial facilities, it provides peace of mind by combining durable materials, thoughtful engineering, and compliance with vital safety codes.\n\u003c\/p\u003e \u003cbr\u003e \u003ctable id=\"product-attribute-specs-table\" class=\"data table additional-attributes\"\u003e\n\u003ccaption class=\"table-caption\"\u003e\n\u003cdiv class=\"product-info-manufacturer\" style=\"text-align: left;\"\u003e\n\u003cdiv class=\"product attribute manufacturer\"\u003e\n\u003cspan class=\"type\"\u003eBrand:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"value\"\u003eViking\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product attribute overview\"\u003e\n\u003cdiv class=\"value\"\u003e\n\u003cp style=\"text-align: left;\"\u003eViking EasyPac Commercial Riser Manifold Assemblies are available in sizes 1-1\/4”, 1-1\/2”, 2”, 2-1\/2”, 3”, 4”, 6” and 8” for commercial systems. They are available with an AGF TESTanDRAIN valve, and\/or pressure relief valve (PRV) to meet NFPA 13 requirements for gridded systems and any system requiring a pressure relief valve. This configuration eliminates the need to drain the system before installing the relief valve, while a built in test port allows hydrostatic testing without draining the system.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eEasyPac Commercial Assemblies are designed with all required equipment and standard components that can be replaced in the field, including pressure gauges, Potter flow switches, 3-way gauge control valve and appropriate drain valve. All assemblies are available in grooved inlet and outlet connections 1-1\/4”-8” using Schedule 10 steel pipe. The 1-1\/4” to 2” assemblies are also available with male NPT threaded inlets and outlets, or threaded inlets x grooved outlets using Schedule 40 steel pipe.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003e\u003ca href=\"https:\/\/www.vikinggroupinc.com\/sites\/default\/files\/migrated\/102307.pdf\" title=\"TECHNICAL DATA SHEET\"\u003eTECHNICAL DATA SHEET\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eItem Number\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd data-th=\"Item Number\" class=\"col data\"\u003e8430AS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eBrand\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd data-th=\"Brand\" class=\"col data\"\u003eAGF Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eBox Quantity\u003c\/span\u003e\u003c\/th\u003e\n\u003ctd data-th=\"Box Quantity\" class=\"col data\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fire Protection Parts","offers":[{"title":"Default Title","offer_id":43296172277850,"sku":"8420AS","price":873.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/0637\/7818\/files\/2-12-commercial-riser-with-pressure-reducing-valve-7530730.png?v=1777602113","url":"https:\/\/patriotsafesource.com\/products\/2-1-2-commercial-riser-with-pressure-reducing-valve","provider":"Patriot SafeSource","version":"1.0","type":"link"}