{"product_id":"automatic-air-release-float-vent-for-fire-sprinklers","title":"Automatic Air Release Float Vent for Fire Sprinklers","description":"\u003cdiv\u003e\n\u003cp\u003e\nThe Automatic Air Release Float Vent (PAAR-B) by Potter Electric Signal is an essential component designed to enhance the performance and reliability of fire sprinkler systems in commercial and industrial buildings. This device automatically vents trapped air during system fill and operation, ensuring optimal water flow and system responsiveness when fire protection matters most.\n\u003c\/p\u003e \u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eMaterial Construction\u003c\/b\u003e: Made from durable, corrosion-resistant brass alloy with a stainless steel internal float and heat-resistant EPDM elastomer seals, resisting wear in pressurized, wet environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAutomatic Air Release Mechanism\u003c\/b\u003e: Features a precision internal float that senses rising water levels to close the vent tightly, preventing water leakage while continuously releasing trapped air to maintain system integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eRegulatory Compliance\u003c\/b\u003e: Fully UL listed for automatic air vents in fire protection, FM approved, and meets NFPA 13 standards for reliable safety and performance in fire sprinkler systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCompatibility and Installation\u003c\/b\u003e: Designed for sprinkler systems operating up to 175 psi (12.1 bar) with a standard 1-inch NPT connection, allowing seamless installation without needing additional adapters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eMaintenance Benefits\u003c\/b\u003e: By efficiently expelling air pockets that cause corrosion and detection delays, it reduces false alarms, lowers maintenance frequency, and extends system lifespan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOptimized for Large-Scale Use\u003c\/b\u003e: Engineered specifically for high-occupancy and commercial buildings, improving waterflow detector sensitivity and overall sprinkler response times.\u003c\/li\u003e\n\u003c\/ul\u003e \u003cp\u003e\nBy constantly removing trapped air, the PAAR-B supports earlier fire detection and reliable sprinkler activation, enhancing safety in complex fire protection setups. Its robust materials and proven design minimize corrosion and false alarms, helping facility managers maintain fire safety systems with reduced downtime and costs. This automatic air release vent ensures your fire sprinkler system operates at peak efficiency, providing peace of mind for building occupants and safety personnel alike.\n\u003c\/p\u003e \u003cbr\u003e \u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e\n\u003ccaption class=\"table-caption\"\u003eMore Information\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eItem Number\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Item Number\"\u003ePAAR-B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Weight\"\u003e13.100000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBox Quantity\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Box Quantity\"\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCrate Quantity\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Crate Quantity\"\u003e1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDescription\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Description\"\u003eAUTOMATIC AIR RELEASE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Brand\"\u003ePotter Electric Signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003ePrice Group\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Price Group\"\u003eSR027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003ePricing UOM\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Pricing UOM\"\u003eEA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSearch Text\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Search Text\"\u003eAIR RELEASE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eVendor Part Number\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Vendor Part Number\"\u003e1030001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fire Protection Parts","offers":[{"title":"Default Title","offer_id":43296134168666,"sku":"PAAR-B","price":1684.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/0637\/7818\/files\/automatic-air-release-float-vent-for-fire-sprinklers-4596748.jpg?v=1777601195","url":"https:\/\/patriotsafesource.com\/products\/automatic-air-release-float-vent-for-fire-sprinklers","provider":"Patriot SafeSource","version":"1.0","type":"link"}