{"product_id":"np-2-threaded-sprinkler-escutcheon-3-diameter","title":"NP-2 Threaded Sprinkler Escutcheon 3\" Diameter","description":"\u003cdiv\u003e\n\u003cp\u003eThe Viking NP-2 Threaded Sprinkler Escutcheon is a dedicated trim component engineered for commercial and industrial fire protection assemblies utilizing threaded sprinkler connections. Installed directly at ceiling penetrations in wet, dry, or preaction fire sprinkler systems, this two-piece assembly bridges the gap between the sprinkler drop and the ceiling opening. It provides a clean aesthetic finish while maintaining structural integrity around the fire suppression hardware.\u003c\/p\u003e \u003cp\u003eThis component satisfies rigorous life safety criteria by complying with NFPA 13 installation guidelines for fire sprinkler systems. The design ensures proper fit and alignment for recessed or adjustable escutcheon configurations, directly satisfying code requirements for gap-free ceiling penetration and unhindered sprinkler discharge patterns.\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eTwo-Piece Assembly:\u003c\/strong\u003e Combines an outer cup and a threaded adapter to simplify installation and accommodate ceiling or pipe alignment variations.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eOuter Diameter:\u003c\/strong\u003e Features a 3-1\/8 inch (80 mm) outer diameter engineered to fit standard commercial ceiling openings precisely.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built from robust materials designed to withstand demanding commercial and industrial fire safety environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eService Accessibility:\u003c\/strong\u003e Easily removable and reinstallable to access equipment above removable ceiling panels without shutting down the system or removing the sprinkler head.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e Supports recessed or adjustable configurations across standard threaded fire sprinkler setups.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e \u003ccaption class=\"table-caption\"\u003eTechnical Specifications \u0026amp; Compliance\u003c\/caption\u003e \u003ctbody\u003e \u003ctr\u003e \u003cth class=\"col label\" scope=\"row\"\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/th\u003e \u003ctd class=\"col data\" data-th=\"Manufacturer \/ Brand\"\u003eViking\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth class=\"col label\" scope=\"row\"\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/th\u003e \u003ctd class=\"col data\" data-th=\"Model \/ Series Number\"\u003eNP-2 \/ Item 22067\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth class=\"col label\" scope=\"row\"\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/th\u003e \u003ctd class=\"col data\" data-th=\"Connection\"\u003eThreaded Sprinkler Connection\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth class=\"col label\" scope=\"row\"\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/th\u003e \u003ctd class=\"col data\" data-th=\"Material\"\u003eDurable Fire Safety Grade Materials\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth class=\"col label\" scope=\"row\"\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/th\u003e \u003ctd class=\"col data\" data-th=\"Listings\"\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003cth class=\"col label\" scope=\"row\"\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/th\u003e \u003ctd class=\"col data\" data-th=\"NFPA Standards\"\u003eNFPA 13\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eVerify local Authority Having Jurisdiction (AHJ) requirements and consult manufacturer technical data sheets before beginning installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"#\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e\n\u003ccaption class=\"table-caption\"\u003eMore Information\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eItem Number\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Item Number\"\u003e 22067 \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eBrand\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Brand\"\u003e Viking \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fire Protection Parts","offers":[{"title":"Chrome \/ 1\/2 in.","offer_id":68031300075610,"sku":"sku-46395090174200","price":2.99,"currency_code":"USD","in_stock":true},{"title":"Chrome \/ 3\/4 in.","offer_id":68031300108378,"sku":"22072F","price":3.99,"currency_code":"USD","in_stock":true},{"title":"White \/ 1\/2 in.","offer_id":68031300141146,"sku":"22067M\/W","price":2.99,"currency_code":"USD","in_stock":true},{"title":"White \/ 3\/4 in.","offer_id":68031300173914,"sku":"22072M\/W","price":3.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/0637\/7818\/files\/np-2-threaded-sprinkler-escutcheon-646905.png?v=1794374428","url":"https:\/\/patriotsafesource.com\/products\/np-2-threaded-sprinkler-escutcheon-3-diameter","provider":"Patriot SafeSource","version":"1.0","type":"link"}