{"product_id":"vk547-quick-response-fire-sprinkler-36","title":"VK547 Quick Response Fire Sprinkler 36\"","description":"\u003cdiv\u003e\n\u003cp\u003eThe Viking VK547 Quick Response Fire Sprinkler 36\" functions as an automatic fire suppression discharge component, engineered to detect heat promptly and initiate water flow to limit fire spread and damage. It installs directly into wet pipe and dry pipe fire suppression assemblies, integrating seamlessly with existing piping and control systems to protect commercial and residential assets and personnel.\u003c\/p\u003e \u003cp\u003eThis sprinkler satisfies mandatory life safety guidelines under \u003cstrong\u003eNFPA 13\u003c\/strong\u003e, which governs the installation of fire sprinkler systems to ensure operational reliability, efficiency, and safety. Compliance with these standards guarantees that your installation meets essential regulatory requirements and industry best practices.\u003c\/p\u003e \u003ch2\u003eKey Features \u0026amp; Construction\u003c\/h2\u003e\n\u003cul\u003e \u003cli\u003e\n\u003cstrong\u003eDurable Construction:\u003c\/strong\u003e Built using high-grade brass and steel components to provide exceptional resistance to corrosion across diverse environmental conditions.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eQuick Response Technology:\u003c\/strong\u003e Engineered for rapid heat detection and swift discharge activation to protect critical environments.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSystem Versatility:\u003c\/strong\u003e Integrates directly with both wet pipe and dry pipe fire sprinkler networks.\u003c\/li\u003e \u003cli\u003e\n\u003cstrong\u003eSimplified Installation:\u003c\/strong\u003e Designed for straightforward integration with existing control systems to minimize labor time and installation costs.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ch2\u003eTechnical Specifications \u0026amp; Compliance Table\u003c\/h2\u003e\n\u003ctable class=\"data table additional-attributes\"\u003e \u003cthead\u003e \u003ctr\u003e \u003cth scope=\"col\"\u003eTechnical Field\u003c\/th\u003e \u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eViking\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number \/ SIN\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eVK547 (Item Number: 19828FG36)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e1-1\/4-inch NPT\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePressure Rating (WWP)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e175 psi (12 bar) maximum working pressure\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eK-Factor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003e11.2 U.S. (161.3 metric)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Rating \/ Response Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eQuick Response\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBrass and Steel\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eUL Listed, FM Approved\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 13\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eContractors must verify all local Authority Having Jurisdiction (AHJ) mandates and consult the manufacturer technical data sheets prior to assembly and installation.\u003c\/p\u003e \u003cp\u003e\u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"#\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ctable id=\"product-attribute-specs-table\" class=\"data table additional-attributes\"\u003e\n\u003ccaption class=\"table-caption\"\u003eMore Information\u003c\/caption\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eItem Number\u003c\/th\u003e\n\u003ctd data-th=\"Item Number\" class=\"col data\"\u003e19828FG36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eBrand\u003c\/th\u003e\n\u003ctd data-th=\"Brand\" class=\"col data\"\u003eViking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"col label\"\u003eBox Quantity\u003c\/th\u003e\n\u003ctd data-th=\"Box Quantity\" class=\"col data\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Fire Protection Parts","offers":[{"title":"Default Title","offer_id":68031293554778,"sku":"19828FxG36","price":377.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0655\/0637\/7818\/files\/vk547-quick-response-qr-pln-pd-ch-280-36-799040.png?v=1794374369","url":"https:\/\/patriotsafesource.com\/products\/vk547-quick-response-fire-sprinkler-36","provider":"Patriot SafeSource","version":"1.0","type":"link"}